Manufacturer download-center manual; check power, sync wiring and low-temperature startup. Applies to MID-360, not S / L variants.
MID-360
Livox
Livox · Shenzhen
Legal correspondence address in Hong Kong; Shenzhen directory pin is unverified
40th Floor, Sunlight Tower, 248 Queen's Road East, Wanchai, Hong Kong
Check these before requesting a quote
- Application
- Mobile sensing / ranging; distinguish scanning LiDAR from single-point sensors and verify test conditions.
- Interfaces & integration
- 100BASE-TX Ethernet
- MOQ
- To be confirmed
- Project-specific price
- To be confirmed — configuration, quantity, tax and freight required
- Lead time
- To be confirmed
- Specification source checked
- 2026-11-07
0.1–0.2 m returns are reference only; range precision is not guaranteed there. Legacy Shenzhen coordinates have not been confirmed. Official Hong Kong address is legal correspondence, not a Shenzhen factory.
Manufacturer manuals & specification references
Official firmware and mechanical-model entry. Confirm the installed firmware and cable revision.
Official manufacturer product / contact page. Exact order configuration, availability, MOQ, project price and lead time require written confirmation.
Development & integration
RobotBay curation & document review · 2026-11-08
Document review checks the correspondence between the cited material and our summary. It is not performance certification, hardware testing or a purchase recommendation. Manufacturer documentation, community runs and RobotBay tests are separate evidence.
Review scope & evidence
- Review record
- RB-DOC-MID-360
- Model reviewed
- MID-360
- Reviewer & date
- RobotBay · documentation desk · 2026-11-08
- What was checked
- MID-360 named in SDK and driver; network configuration, API declarations and distribution build instructions reviewed.
- Not checked
- No hardware connection, build, simulation run, performance or purchase recommendation. Firmware/host combinations not listed below remain unconfirmed.
Dates record an actual review, not a deployment. Online documents and default branches may change afterwards.
Communication & protocol
Official documentation · summary checkedEthernet/IP; separate command, point-data and IMU ports in MID360 configuration.
Official ROS / ROS 2 driverCommands you can send
Official documentation · summary checkedDevice configuration and LiDAR work-mode APIs; no robot joint-control capability implied.
Livox LiDAR API headerFeedback you can read
Official documentation · summary checkedLiDAR point data and IMU streams; actual enabled outputs depend on configuration.
Official ROS / ROS 2 driverLivox LiDAR API headerDeveloper access & restrictions
Official documentation · summary checkedSDK2 and driver are public; installed firmware and redistribution terms still need project-specific review.
Official Livox SDK2ROS / ROS 2 & versions
Official documentation · summary checkedREADME lists Melodic, Noetic, Foxy, Humble and Jazzy with different build targets.
Official ROS / ROS 2 driverSimulation / URDF / models
UnconfirmedUnconfirmed. Model- and version-specific documentation is still needed.
Assembly documentation
UnconfirmedUnconfirmed. Model- and version-specific documentation is still needed.
Calibration documentation
UnconfirmedUnconfirmed. Model- and version-specific documentation is still needed.
Official resources & applicable versions
MID-360 supported device
master README · Checked 2026-11-08 · Official link; original terms applyDevice configuration and callback declarations
master API header · Checked 2026-11-08 · Official link; original terms applyMID360 network configuration and supported OS/ROS
master README · Checked 2026-11-08 · Official link; original terms applyIntegration & hardware evidence
Community integration report: no reviewed report with an environment, steps and run evidence yet.
RobotBay hardware test: not performed; these SDKs have not been built or run against hardware by RobotBay.
Versions & specifications
Displayed configuration: MID-360. Not applicable to every version.
Manufacturer specifications · 14
- Detection range
- 40 m @10% / 70 m @80% reflectivity, 100 klx ↗
- Field of view
- H360° / V−7° to 52° ↗
- Point rate
- 200,000 points/s, first return ↗
- Frame rate
- 10 Hz typical ↗
- Supply voltage
- 9–27 V DC ↗
- Average power
- 6.5 W ↗
- Mass
- 265 g ↗
- Dimensions
- 65×65×60 mm ↗
- Ingress protection
- IP67 ↗
- Interface
- 100BASE-TX Ethernet ↗
- Data synchronization
- IEEE 1588-2008 PTPv2 / GPS ↗
- Integrated IMU
- ICM40609 ↗
- Operating temperature
- −20 to 55 °C; thermal conditions apply ↗
- Cold-start peak power
- Up to 14 W during low-temperature self-heating ↗
Configuration notes and limitations · 2
- Manufacturer-published specifications; confirm configuration, duty cycle, thermal conditions, MOQ and lead time before purchase.
- 0.1–0.2 m returns are reference only; range precision is not guaranteed there. Legacy Shenzhen coordinates have not been confirmed. Official Hong Kong address is legal correspondence, not a Shenzhen factory.
Reference price record
Confirm with manufacturer
Not a live quote. Confirm configuration, currency, tax, shipping, stock and delivery with the manufacturer.
Official MID-360 product illustration; do not substitute MID-360S / MID-360L specifications.
Image from the manufacturer’s website or official manual. Framing is standardized; the product is not redrawn. Appearance may vary by configuration.
View official image source ↗References
MID-360 ↗Source stage label: Manufacturer-published reference. Not independently verified by RobotBay. Listing does not endorse performance or delivery capability.
How to check a specification with RobotBay’s Spec-Claim Check
